Sign In | Join Free | My burrillandco.com
Home > Konica Chroma Meter Spectrophotometer >

Konica Minolta SPAD 502 Plus Chlorophyll Meter chlorophyll analyzer chlorophyll tester with Data-logging model (2900PDL)

    Buy cheap Konica Minolta SPAD 502 Plus Chlorophyll Meter chlorophyll analyzer chlorophyll tester with Data-logging model (2900PDL) from wholesalers
     
    Buy cheap Konica Minolta SPAD 502 Plus Chlorophyll Meter chlorophyll analyzer chlorophyll tester with Data-logging model (2900PDL) from wholesalers
    • Buy cheap Konica Minolta SPAD 502 Plus Chlorophyll Meter chlorophyll analyzer chlorophyll tester with Data-logging model (2900PDL) from wholesalers

    Konica Minolta SPAD 502 Plus Chlorophyll Meter chlorophyll analyzer chlorophyll tester with Data-logging model (2900PDL)

    Ask Lasest Price
    Brand Name : Konica minolta
    Model Number : SPAD 502 Plus
    Certification : CE, ISO9001, ROHS, FCC, TUV, SCM
    Price : 1500 usd
    Payment Terms : T/T, L/C, Western Union
    Supply Ability : 100000
    Delivery Time : 2 days
    • Product Details
    • Company Profile

    Konica Minolta SPAD 502 Plus Chlorophyll Meter chlorophyll analyzer chlorophyll tester with Data-logging model (2900PDL)

    Konica Minolta SPAD 502 Plus Chlorophyll Meter chlorophyll analyzer chlorophyll tester with Data-logging model (2900PDL)

    Specifications

    1. SPAD 502 PLUS
    2. chlorophyll analyzer
    3. chlorophyll tester

    SPAD-502 Plus Konica chlorophyll meter made in japn

    chlorophyll meter, chlorophyll analyzer, chlorophyll tester


    SPAD 502 Plus Chlorophyll Meter

    The SPAD 502 Plus Chlorophyll Meter instantly measures chlorophyll content or “greenness” of your plants to reduce the risk of yield-limiting deficiencies or costly overfertilizing. The SPAD 502 Plus quantifies subtle changes or trends in plant health long before they’re visible to the human eye. Non-invasive measurement; simply clamp the meter over leafy tissue, and receive an indexed chlorophyll content reading (-9.9 to 199.9) in less than 2 seconds. Assess nitrogen needs by comparing in-field SPAD readings to university guidelines or to adequately fertilized reference strips. Research shows a strong correlation between SPAD measurements and leaf N content.

    • Instantly measures chlorophyll content or “greenness” of your plants on a scale of -9.9 to 199.9
    • Non-invasive, non-destructive measurement
    • Trend graph stores and displays up to 30 measurements
    • Waterproof design
    • Compare in-field SPAD readings to university guidelines
    • Research shows a strong correlation between SPAD measurements and leaf N content
    • Available with or without a built-in data logger
    • Includes hard carrying case and batteries


    Data-logging model (2900PDL)

    • Connects to any GPS receiver that has a serial output option*
    • Equipped with internal data logger and RS-232 port
    • Records 4,096 measurements (1,488 with added GPS/DGPS option)
    • Configure and download meter with FieldScout® software and USB-to-3.5mm-Stereo-Plug Adapther (Item 3661U.(included)**
    • Compatible with SpecMaps™ online web-mapping application


    * GPS interface requires two cables. The GPS/DGPS cable (item 2950CV5) is available from Spectrum. A PC serial interface cable supplied by the manufacturer of the GPS receiver is also required.
    ** PC cable connects to a computer USB port.


    Chroma Meter CL-200 of Konica Minolta


    Handheld and lightweight instrument for color, illuminance and color temperature measurements.


    Practically anything that illuminates can be measured with Konica Minolta's incident color meters. The possible uses range from research and development to production.


    The CL-200 is a lux meter with a color function for workplace and street illumination, the production of lamps, or the measurement of very large surfaces and projectors (ANSI lumens) by taking advantage of the serial connection of several receptor heads.


    The CL-200 is a replacement for two instruments - the CL-100 and XY-1- and includes many new features. Immediate measurement is possible from turning on the unit by quick automatic zero adjustment so it is always ready to move at the speed of light. Sometimes it is necessary to measure remotely for matters of safety or convenience so the CL-200 receptor can be separated and connected up to 100m away from the measuring body by LAN cable. An RS-232 interface is built in to allow connection to PC and connection to thermal printer is also optional should a printout of measured data be required for validation.


    Features

    • Compact - hand-held, lightweight design
    • Portable - battery operated, receptor head can also be detached from the main body for remote measurements
    • User-friendly - low battery indicator, can be controlled by a PC, easily transfer data to Excel, and includes a calibration function
    • Simultaneous measurements - has the ability to determine illuminance, color temperature, chromaticity, dominant wavelength, and excitation purity of a light source
    • Ideal for white LEDs - can measure the chromaticity from the phosphor as well as inspect the final product
    • Multi-use - can be used for any light source, ideal for LEDs and OLEDs
    • LED ranking function - using the included software, users can rank measurements on a chromaticity chart for easy comparison
    • A single unit used for data display and key operations can be connected to as many as 30 receivers.
    • Automatic calibration
    • PC and printer access
    • PC-Software optional
    • Leasing from ca. 59,00 Euro net monthly

    Specifications:

    ModelIncident Color Meter CL-200
    Relative spectral responseClosely matches CIE standard observer curves x(?), y(?), and z(?)
    Within 8% (f1') of the CIE spectral luminous efficiency V(?)
    ReceptorSilicon photocell
    Measurement functionsTristimulus values:XYZ
    Chromaticity coordinates:Ev xy, Ev u'v'
    Correlated color temperature:Ev, Tcp, ?uv
    Color difference:?(XYZ), ?(Ev xy), ?(Ev u'v'), ?Ev?u'v'
    (One target color)
    Other functionsUser calibration function, Data hold function, Multi-point measurement (2 to 30 receptors)
    Measuring range0.1 to 99,990 lx, 0.01 to 9,999 fcd (Chromaticity: 5 lx, 0.5 fcd or above) in four automatically selected ranges
    AccuracyEv: ±2%, ±1 digit of displayed value (based on Konica Minolta standard)
    xy: ±0.002 (800 lx, Standard Illuminant A measured)
    RepeatabilityEv: 0.5% ±1 digit (2?) xy: ±0.0005 (800 lx, Standard Illuminant A measured)
    Temperature driftEv: ±3%, ±1 digit of displayed value xy: ±0.003
    Humidity driftEv: ±3%, ±1 digit of displayed value xy: ±0.003
    Response time0.5 sec. (continuous measurement)
    Digital outputRS-232C
    Display4 Significant-digit LCD with back-light illumination
    Operating temperature/humidity range-10 to 40°C, relative humidity 85% or less (at 35°C) with no condensation
    Storage temperature/humidity range-20 to 55°C, relative humidity 85% or less (at 35°C) with no condensation
    Power source2 AA-size batteries / AC adapter (optional)
    Battery life72 hours or longer (when alkaline batteries are used in continuous measurement
    Dimensions69 × 174 × 35mm (2-3/4 × 6-7/8 × 1-3/8 in.)
    Weight215g (7.6 oz) not including batteries
    Standard accessoriesSoft case, lens cap, neck strap, batteries
    Optional accessoriesAdditional receptors, Adapter Unit for Main Body T-A20; Adapter Unit for Receptor Head T-A21; AC Adapter AC-A10 (AC-A10N in North America); Data Management Software CL-S1w; Printer Cable T-A12; Connecting Cable T-A11 (for PC); Hood CL-A11; Hard Case CL-A10

    C7000 LUX METER


    Lighting solutions and applications have never been in greater demand and expansion as they are today. With the overwhelming popularity of these new light sources such as advanced LED and Organic Electroluminescence, the need to understand, manage and control these sophisticated illumination systems is essential. Manufacturing quality and process along with varying color and illumination qualities can often result in consistency issues. To address these lighting challenges, Sekonic Corporation, a leader for over six decades providing advanced precision lighting control for the Photo / Video / Cine industry has offered an ergonomic, intuitive Spectrometer, the SPECTROMASTER C-7000.


    The new SPECTROMASTER C-7000 is a portable handheld spectrometer, designed especially for industrial use. Utilizing Sekonic’s CMOS linear image sensor design and software, the
    C-7000 can measure every light source (LED, HMI, fluorescent, natural light and electronic flash spectrum) with remarkable precision and data feedback.


    Measures LED, HMI, Fluorescent, Tungsten, Natural Light and Flash in 1 nanome- ter (nm) output wavelength increments from 380 to 780 nm. It conforms to re- quirement of “Illuminance meter class” for JIS C 1609-1: 2006 “Illuminance meters Part 1: General measuring instruments” Class A, and DIN 5032 Part 7 Class C.


    With the C-7000 Utility software, output of memorized data is provided at every 1nm (nanometer) increments in CSV format. The C-7000 can be utilized to measure data for light manufactures quality control, medical facilities, educational / office safety and health standards, agricultural lighting / design and many more industrial uses.

    C7000-2.png

    Wide Measurement Range of Color Temperature and Illuminance

    Wide measurement range of Color Temperature (1,563 to 100,000K) and illumination (1 to 200,000lx = 0.1 to 18,600fc in ambient light, 20 to 20,500lx • s = 1.86 to 1,900fc • s in flash light)

    User-Friendly Design

    270º swivel head, dark calibration without cap, large 4.3” color touch panel LCD and Customize function, convenient AA batteries for power source.


    Various Display Items

    Various Display Items

    * Correlated color temperature (Tcp),
    * CIE1931(CIE1964) Chromaticity Coordinates
    * CIE1976 Chromaticity Coordinates
    * Lux(lx) or Foot-Candle(fc) – ambient light
    * Lux sec. (Hlx) or Foot-Candle sec. (Hfc)–flash light
    * Tristimulus Value (X ,Y ,Z)
    * Deviation ( Delta uv)
    * CRI (Ra / R1 to R15)
    * Peak Wavelength (λp)
    * Dominant Wavelength (λd)
    * Purity (Pe)
    * PPFD: Photosynthetic Photon Flux Density (μmolm-2s-1)


    C-7000 Specifications

    Display Items Library


    Illuminance Meter Class

    * Class A of JIS C 1609-1: 2006 “Illuminance meters Part 1: General measuring instruments”

    * DIN 5032 Part 7 Class C

    SensorCMOS linear image sensor
    Spectral Wavelength Range380nm to 780nm
    Output Wavelength Pitch1nm (Requires the C-7000 Utility to output memorized data)
    Spectral BandwidthApprox. 11 nm (half bandwidth)
    Measuring RangeAmbient light: 1 to 200,000lx (= 0.1 to 18,600fc), 1,563 to 100,000K (more than 5lx required)
    Flash light: 20 to 20,500lx • s (= 1.86 to 1,900fc • s), 1,563 to 100,000K
    Accuracy (Standard Illuminant A)Illuminance: ±5% + 1digit (1 to 3,000lx)
    x,y: 0.003 (Standard Illuminant A, 800lx)
    Repeatability (Standard Illuminant A)Illuminance: 1%+1 digit (30 to 200,000lx), 5%+1 digit (1 to 29.9lx)
    x,y: 0.001 (500 to 200,000lx)
    x,y: 0.002 (100 to 499lx)
    x,y: 0.004 (30 to 99.9lx)
    x,y: 0.008 (5 to 29.9lx)
    Visible-region Relative Spectral Response Characteristics (f1’)9% or less
    Cosine Response (f2)6% or less
    Temperatutre CharacteristicIlluminance: ±5% of indicated value
    x,y: ±0.006 (Standard Illuminant A, 1000lx)
    Humidity CharacteristicIlluminance: ±3% of indicated value
    x,y: ±0.006 (Standard Illuminant A, 1000lx)
    Power SourceAA (1.5V) x 2 pcs, USB bus power
    Measurement TimeAmbient: Auto - Max.: 15 sec., Min.: 0.5 sec.
    Ambient : Manual - 0.1s, 1sec.
    Flash: 1 to 1/500 sec. (in 1 step)
    Measuring ModesText mode, Spectrum mode, Spectrum Comparison mode, CRI mode, CIE1931 (CIE1964) mode, CIE1931 (CIE1964) Comparison mode, CIE1976 mode, CIE1976 Comparison mode
    Other FunctionsUp to 999 memory, Preset function, Auto power off, Auto Dimmer, 2 or 10 deg. Filed of View Setting
    Display languagesEnglish, Japanese, Chinese (Simplified) - factory preset, user cannot change.
    InterfaceUSB 2.0
    Operating Temperature-10 to 40 ºC
    Storage Temperature-10 to 60 ºC
    Dimensions

    73mm (w) × 183mm (h) × 27mm (d) = 2.9” (w) x 7.2” (h) x 1.1” (d)

    (excluding protruding part of light receiving) max. thickness 40mm (d) = 1.6” (d)

    Weight230g without batteries

    Company Information

    3nh Colorimeter Company


    Other products:


    20170321145019_52205QQ20151106092430NH310P120contact us


    Quality Konica Minolta SPAD 502 Plus Chlorophyll Meter chlorophyll analyzer chlorophyll tester with Data-logging model (2900PDL) for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen 3nh Technology CO., LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2024 burrillandco.com. All rights reserved.